Welders & Plasma

Welder comparison table: duty cycle, input amps and breaker by model

Eleven welders side by side on published rated output, minutes of arc per ten, input amps and required circuit. Every figure sourced and dated.

This is the reference table the rest of the site links to. It holds one thing: what each manufacturer publishes about rated output, arc time and what the machine needs from the wall.

Read across a row to see whether a machine fits your circuit. Read down a column to see which makers publish what you need to plan one. Minutes of arc per ten is the only figure we derive (duty cycle times ten). Everything else is printed as published, and gaps are marked.

120 volt input

Figures for dual voltage machines on their 120 volt side. “110” and “115” are the makers’ own labels for the same household outlet.

MachineRated outputMinutes of arc per tenInput amps as publishedCircuit or breaker as published
Lincoln WELD-PAK 90i FC (K5255-1)90 A at 30 percent3I1max 21, I1eff 11.5 (spec sheet: 20)Rated output available on a 20 A branch circuit
Hobart Handler 14090 A at 20 percent22020 A individual branch circuit
Hobart Handler 210 MVP90 A at 20 percent22020 A individual branch circuit
Lincoln POWER MIG 210 MP (K3963-1)100 A at 40 percent415 (not labeled max or effective)20 A fuse or breaker
Weldpro MIG210LCD120 A at 30 percent335.7 rated (manual), I1eff 24.3 (spec sheet)Not published
YesWelder MCT-520130 A at 60 percent6I1max 37, I1eff 24 (mig)Not published
YesWelder FLUX-135PRO135 A at 60 percent6I1max 54, I1eff 4050 A time-delay breaker (troubleshooting section)
ARCCAPTAIN MIG13560 percent, amperage not published647.6 rated50 A branch circuit
ARCCAPTAIN MIG205MP140 A at 60 percent (tig and stick; mig not published)6I1max 46, I1eff 20.550 A branch circuit
YesWelder MIG-205DS160 A at 60 percent6I1max 43, I1eff 33.2Not published
ARCCAPTAIN MIG20060 percent, amperage on graph only644.2 ratedBreaker over 50 A

The pattern is plain. The four machines at the top are rated inside what a household circuit supplies, about 2,400 watts on 20 amps. The seven below publish input currents of 35 to 54 amps on the same outlet. They run there at reduced settings, and no maker publishes how reduced. Background in welder amp draw and 110v vs 220v welders.

240 volt input

MachineRated outputMinutes of arc per tenInput amps as publishedCircuit or breaker as published
Hobart Handler 210 MVP150 A at 30 percent324See manual OM-260 274, section 5-8
Lincoln POWER MIG 210 MP (K3963-1)200 A at 25 percent2.514.7 (not labeled max or effective)40 A fuse or breaker
Weldpro MIG210LCD200 A at 30 percent335.7 rated (manual), I1eff 23 (spec sheet)Not published
YesWelder MCT-520200 A at 60 percent6I1max 41, I1eff 30 (mig)Not published
ARCCAPTAIN MIG205MP205 A at 60 percent (tig and stick; mig not published)6I1max 35.6, I1eff 15.550 A branch circuit
YesWelder MIG-205DS205 A at 60 percent6I1max 34, I1eff 26.3Not published
ARCCAPTAIN MIG20060 percent, amperage on graph only630.9 ratedBreaker over 50 A

Wire gauge for the supply circuit is published by Lincoln (12 AWG copper for the POWER MIG 210 MP on either voltage, per its input table) and by Hobart in its Electrical Service Guide. None of the import brands publishes one. Generator size is not published for any machine here.

How the duty cycle figures compare

The Hobart and Lincoln machines publish 20 to 40 percent. The import brands publish 60. We do not know that these were measured the same way. IEC 60974-1 sets a ten minute window at 40 C (104 F). Lincoln’s 90i FC rating plate cites the standard and ArcCaptain names it. YesWelder and Weldpro give an operating range up to 40 C without linking it to the rating. Until a maker states the basis, treat the comparison between the two groups as unproven. More in duty cycle as minutes of arc.

Sources

All checked 2026-09-19.

Brand notes: YesWelder and ArcCaptain. Our ranked picks from these machines are in best multiprocess welders and best welder for beginners. The breaker and wire figures are the manufacturers’ statements, printed so you can have an informed conversation. Planning and installing a circuit is a licensed electrician’s job, and we do not publish wiring instructions.

Next step Best multiprocess welders, ranked by what they need from the wall

Frequently asked questions

Why do some cells say Not published?

Because the manufacturer does not state that figure in its manual, spec sheet or product page, and we do not estimate. A missing input current or breaker size means you and your electrician have less to plan with, so the gap is worth knowing before you buy.

Why do budget welders show 60 percent duty cycle when Hobart and Lincoln show 20 to 40?

Those are the figures each maker publishes. The international standard, IEC 60974-1, rates duty cycle over ten minutes at 40 C (104 F). Lincoln's rating plate cites it, and ArcCaptain names it in its spec tables. YesWelder and Weldpro do not tie their duty cycle to a temperature or standard in the documents we read, so the two sets of numbers may not be measured the same way.

Which input amps figure should I give my electrician?

All of them, with the manual. I1max is the draw while the arc is on at maximum rated output, and I1eff is the effective draw once duty cycle is counted. Some manuals print a single rated input current without saying which it is. Planning the circuit from those figures is a licensed electrician's job.

Disclosure: Rated Arc is reader-supported. We are a participant in the Amazon Services LLC Associates Program, an affiliate advertising program designed to provide a means for sites to earn advertising fees by advertising and linking to Amazon.com. When you buy through links on our site, we may earn a commission at no extra cost to you. We only recommend products we would use ourselves, and product photos come from the retailer.